Analytical solution of the use of oblique arms in reducing the forces imposed on brackets of the vertical generator and its foundation
Pooria Akbarzadeh
Shahrood University of Technology , akbarzad@ut.ac.ir
Abstract:   (1824 Views)
In large hydroelectric power-plants with a power of more than 100 megawatts, vertical generators are used, in which the diameter and the weight of their stator exceeding 8 meters and several hundred tons, respectively. In this structure, which is the location of the magnetic plates and the stator core, there are two rings with radial or oblique arms for mounting bearings of rotating parts of the generator (they are called upper and lower brackets). These arms transfer the forces due to the increase in the length of the ring (due to the increase in temperature), the radial forces applied from the turbine, and the torsion hydraulic torque from the turbine axis to the stator or its foundations. Therefore, accurate prediction of these forces and torque in the design of the structure and the calculation of compressive and bending stresses on the structure or foundation of the arms is of particular importance. In this paper, the effect of using oblique arms on the reduction of compressive stresses and the foundation forces of large vertical generators, is analyzed analytically. The effect of angle, length, number, and arrangement of oblique arm on stress and forces for three different load cases are investigated.
Keywords: Analytical solution, oblique arm, oblique arm angle, foundation force, generator bracket
Full-Text [PDF 1132 kb]   (632 Downloads)    
Type of Study: Research | Subject: تجهیزات مکانیکی و هیدرومکانیک
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Akbarzadeh P. Analytical solution of the use of oblique arms in reducing the forces imposed on brackets of the vertical generator and its foundation. Iranian Dam and Hydroelectric Powerplant 2019; 5 (19) :1-12
URL: http://journal.hydropower.org.ir/article-1-289-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 5, Issue 19 (3-2019) Back to browse issues page
نشریه سد و نیروگاه برق آبی Journal of Dam and Hydroelectric Powerplant
Persian site map - English site map - Created in 0.04 seconds with 38 queries by YEKTAWEB 4645