<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Dam and Hydroelectric Powerplant</title>
<title_fa>سد و نیروگاه برق آبی ایران</title_fa>
<short_title>Journal of Dam and Hydroelectric Powerplant</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://journal.hydropower.org.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-5882</journal_id_issn>
<journal_id_issn_online>2322-5882</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1400</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2022</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>8</volume>
<number>31</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بهسازی لرزه‌ای مخازن هوایی استوانه‌ای ذخیره آب به کمک جداسازهای غیرخطی با در نظر گرفتن اندرکنش سیال- سازه</title_fa>
	<title>Improving seismic performance of elevated cylindrical water storage tanks using nonlinear isolators incorporating liquid–structure interaction</title>
	<subject_fa>ژئوتکنیک و مهندسی زلزله</subject_fa>
	<subject>ژئوتکنیک و مهندسی زلزله</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>وسعت احداث مخازن هوایی به عنوان یکی از مهمترین سازه&lt;span dir=&quot;LTR&quot;&gt;&amp;shy;&lt;/span&gt;های تأمین کننده آب بهداشتی شهرها، و ضعف آنها در برابر زلزله، ضرورت تحقیق راجع به روش&#8204;های نوین کنترل غیر فعال این سازه&#8204;ها را دو چندان می&#8204;نماید. از جمله فناوریهای نوین مهندسی زلزله، طراحی جداسازهای لرزه&amp;shy;ای و کاربرد آن در سازه&amp;shy;های خاص از جمله مخازن هوایی محتوی مایع است. در تحقیقات انجام شده تاکنون بررسی خاصی بر روی کارایی این نوع سیستم&amp;shy;ها در کاهش پاسخ لرزه&#8204;ای مخازن هوایی استوانه&amp;shy;ای با در نظر گرفتن انعطاف&amp;shy;پذیری پوسته انجام &#8204;نشده&amp;shy;است. در این پژوهش با انجام تحلیل دینامیکی تاریخچه زمانی، عملکرد لرزه&amp;shy;ای یک مخزن فولادی هوایی بدون و با جداساز تحلیل و نتایج با هم مقایسه شدند. بدین منظور، از دو نوع جداساز هسته&amp;shy;سربی و الاستومری استفاده شده&amp;shy;است. جهت نیل به این هدف، المان&amp;shy;های محدود با رفتار پوسته&#8204;ای برای جداره مخزن، المان&amp;shy;های محدود داخلی برای سیال درون مخزن و المان&amp;shy;های هیسترزیس با رفتار دوخطی برای جداسازها انتخاب گردیده و آنالیز لرزه&amp;shy;ای مخزن انعطاف&amp;shy;پذیر تحت تأثیر زلزله واقعی در حوزه زمان انجام می&amp;shy;شود. نتایج نشان می&amp;shy;دهد که جداسازی افقی علیرغم ایجاد تغییرمکان قابل توجه در سازه، کارایی بیشتری در کاهش پاسخ لرزه&amp;shy;ای سیستم دارد که این موضوع به خصوصیات زلزله بستگی دارد.</abstract_fa>
	<abstract>Pervasive construction of elevated liquid tanks as the most important sources for urban hygienic water, and their failure under earthquake, highlighs the&amp;nbsp;necessity&amp;nbsp;for&amp;nbsp;research toward new passive control devices. Design and use of base-isolation systems for&amp;nbsp;elevated liquid tanks is propounded as a novel seismic engineering technology. To date, no special examination has been discussed in relation with the workability of such systems in reducing the seismic response of elevated liquid tanks considering tank wall flexibility. In this study, the seismic performance of a steel elevated water tank with/without isolator was analyzed and outcomes were evaluated using lead-rubber and elastomeric bearings by performing time-history analyses. To this end, finite shell elements for tank wall and internal finite elements for liquid, and bilinear hysteretic elements for the base-isolation systems are elected, and the&amp;nbsp;seismic&amp;nbsp;analysis&amp;nbsp;of flexible liquid tank is&amp;nbsp;performed in the time domain under real earthquake. The results show that the lateral control device despite excessive structural displacement could offer a substantial benefit for reducing the system&amp;rsquo;s seismic response which depends on the earthquake characterestics.</abstract>
	<keyword_fa>مخزن هوایی مایع, جداسازی پایه, تحلیل لرزه‌ای, روش المان محدود</keyword_fa>
	<keyword>Elevated liquid tank, base-isolation, seismic analysis, finite element method</keyword>
	<start_page>42</start_page>
	<end_page>52</end_page>
	<web_url>http://journal.hydropower.org.ir/browse.php?a_code=A-10-101-3&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mohammad Reza</first_name>
	<middle_name></middle_name>
	<last_name>Shekari</last_name>
	<suffix></suffix>
	<first_name_fa>محمدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>شکاری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>shekari.2291@gmail.com</email>
	<code>2295459516</code>
	<orcid>10031947532846003987</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Estahban Higher Education Center</affiliation>
	<affiliation_fa>مرکز آموزش عالی استهبان</affiliation_fa>
	 </author>


	<author>
	<first_name>Mojtaba</first_name>
	<middle_name></middle_name>
	<last_name>Hasani</last_name>
	<suffix></suffix>
	<first_name_fa>مجتبی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حسنی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mojtabahasani11@gmail.com</email>
	<code>2297069724</code>
	<orcid>10031947532846003988</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Iran University of Science and Technology</affiliation>
	<affiliation_fa>دانشگاه علم و صنعت</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad Reza</first_name>
	<middle_name></middle_name>
	<last_name>Zareifard</last_name>
	<suffix></suffix>
	<first_name_fa>محمدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>زارعی فرد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>zareifard@aut.ac.ir</email>
	<code>2470953006</code>
	<orcid>10031947532846003989</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Estahban Higher Education Center</affiliation>
	<affiliation_fa>مرکز آموزش عالی استهبان</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
